Screen Printing Machine

NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer

NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer
NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer

NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer   NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer

3/6 lead TOUCH SCREEN ECG EKG Electrocardiograph Printer. ECG600G is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for Lead off and Lack of paper, multi-language interface, case database management. 1Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.

2Real-time and continuously record clear and accurate ECG waveform and annotation characterincluding lead mark, sensitivity, paper speed and filter state, etc. 3Full-digital filter design, anti-baseline drift, AC and EMG interference. 4Adjust the baseline automatically, optimize the print setting and optional rhythm leads. 5In AUTO mode, finish recording by pressing the button once, which improves work efficiency. 6Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.

7With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctors burden and improves work efficiency. 8Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc. 9Display of real-time 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.

10Time print can be set to every 1/2/3/5/10/20/30/60 minutes. 11Print setting, including Print and save(print waveform and save case), Print no save(only print waveform but not save case), Save no print(only save case but not print waveform).

12AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time. 13Store more than 1000 cases, convenient for case review and statistic. 14Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakh, Russian, Ukrainian, Vietnamese, Serbian, Slovenian and Slovak) interface and report. Input mode: floating and defibrillation protection.

Input impedance: 2.5 M. Rated input amplitude Input frequency and waveform Relative output response. 1.0 0.67Hz40Hz, Sine wave ±10%a. 0.5 40Hz100Hz, Sine wave +10 %, -30 %a.

0.25 100Hz150Hz, Sine wave +10 %, -30 %a. 0.5 150 Hz 500 Hz, Sine wave +10 %, -100 %a.

1.5 1Hz, 200ms, Triangle wave +0 %, -10 %b. A relative to 10Hz b relative to 200 ms. Filter: power frequency(AC50/60 Hz), EMG25 Hz/35 Hz (-3 dB), baseline drift filter. Recording way: thermal printing system. Specification of recording paper: 110 mm(W)×20 m(L) high-speed thermal paper.

Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%. Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV. Recording mode: auto mode, rhythm mode and manual mode. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1).

Safety classification: Class I, type CF defibrillation-proof applied part. ECG signal input sampling frequency: 32 kHz. Waveform data processing sampling frequency: 1 kHz.

The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected. Pacing detection channel: standard II. Accuracy of input signal: ±5%.

DC: 7.4V/3500mAh rechargeable lithium battery. Degree of protection against ingress of liquid: IPX0. Atmospheric pressure: 700 hPa1060 hPa. Atmospheric pressure: 500 hPa1060 hPa.

Dimension: 315mm(L)×215mm(W)×92mm(H). The item "NEW ECG600G 3/6 LEAD TOUCH SCREEN ECG EKG Electrocardiograph Printer" is in sale since Sunday, June 12, 2016. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\ECG & EKG Machines".

The seller is "conteconline" and is located in Beijing. This item can be shipped worldwide.
  • Number of Channels: 6
  • ECG & EKG Machine Type: Electrocardiograph
  • Number of Leads: 12
  • Model: ECG600G
  • Country/Region of Manufacture: China
  • Mounting: Portable
  • Bundle Listing: Yes
  • Features: Printer
  • Operation: Digital
  • MPN: Does Not Apply
  • Brand: CONTEC
  • Application: Resting